Dr Cindy Thamrin

Senior Research Fellow
Medicine, Central Clinical School
Woolcock Institute of Medical Research

Telephone +61 2 9114 0440
Fax +61 2 9114 0011

Map

Biographical details

Dr. Cindy Thamrin has a dual background in respiratory physiology and electronic engineering. She is a Research Leader at the Woolcock Institute of Medical Research, where she leads the Airway Physiology Group together with Prof. Greg King. She received her PhD in 2006 at the University of Western Australia, where she investigated high frequency respiratory mechanics measured using the forced oscillation technique (FOT), and changes with lung volume could be used to provide insight into chronic obstructive pulmonary disease (COPD).

Dr. Thamrin was postdoctoral fellow at the Children’s University Hospital of Bern, Switzerland. During this time, she became interested in novel methods of analysing respiratory data, and their potential in clinical phenotyping, monitoring, and prediction of future outcomes in airways diseases.

Her work has been recognised by multiple awards including the John Read Prize for Physiology Research by the Thoracic Society of Australia and NZ (TSANZ), and the prestigious Ann Woolcock Award from the American Thoracic Society (ATS) for outstanding contributions and future promise in asthma research.

Research interests

Dr. Thamrin's current research interests are in advanced lung function tests particularly to measure small airway dysfunction, home telemonitoring of lung function using such tests, and novel analyses of respiratory data for clinical prediction and management of airways diseases such as asthma and COPD.

Teaching and supervision

Dr. Thamrin's teaching interests are driven by her interdiscliplinary research, where she frequently serves as an interface between scientists, clinicians and engineers. Between 2009-2010, she initiated, coordinated and taught a semester course on electrical engineering concepts for Master of Biomedical Engineering students with medical/biological backgrounds at the University of Bern, Switzerland. Dr. Thamrin has supervised/co-supervised undergraduate and postgraduate students from a wide range of backgrounds, including clinicians and engineers.

Current research students

Project title Research student
The Respiratory and Cardiovascular Impacts of Orchestral Performance on Trumpet Players: An Observational Cohort Study Liam ACHESON
Clinical utility of advanced analyses of physiological signals in the neonatal intensive care unit Jacqueline HUVANANDANA
Neutrophilic inflammation, alveolar and peripheral airway remodelling in long standing asthma. Katrina TONGA

Current projects

Role of home telemonitoring of lung function using the forced oscillation technique in assessing and predicting asthma control

Prediction of clinical outcomes from home telemonitoring of lung function using the forced oscillation technique in COPD

Associations

2010–present American Thoracic Society (Program Committee member, Respiratory Structure and Function Assembly)

2006–present European Respiratory Society (member)

2002–present The Thoracic Society of Australia & New Zealand (member)

Awards and honours

2013 American Thoracic Society Ann Woolcock Young Investigator Award

2007 Swiss Paediatric Society research meeting/Nestlé Research Award

2007 Pilger Paediatric Respiratory Research Award

2006 Telethon Institute for Child Health Research/Perron Award for Meritorious PhD Performance

2005 Thoracic Society of Australia & New Zealand/Australian Lung Foundation John Read Prize for Physiological Research

In the media

Patents

2014 Sly, Peter, Hantos Zoltan and Thamrin, Cindy. A method of measuring an acoustic impedance of a respiratory system and diagnosing a respiratory disease or disorder or monitoring treatment of same (WO 2006130922 A1).

PhD and master's project opportunities

International links

Italy

(Politecnico di Milano, Milan) Variability analyses of lung function data from home monitoring of forced oscillation for clinical prediction.

Selected grants

2016

  • Home telemonitoring of lung function in chronic lung diseases; Thamrin C; National Health and Medical Research Council (NHMRC)/Career Development Fellowships.

2014

  • Prediction of clinical outcomes in COPD from home monitoring of lung function variability; Thamrin C, King G; National Health and Medical Research Council (NHMRC)/Project Grants.

Selected publications

Download citations: PDF RTF Endnote

Journals

  • Huvanandana, J., Thamrin, C., Tracy, M., Hinder, M., Nguyen, C., McEwan, A. (2017). Advanced analyses of physiological signals in the neonatal intensive care unit. Physiological Measurement, 38(10), R253-R279. [More Information]
  • Pham, T., Leong, P., Robinson, P., Gutzler, T., Jee, A., King, G., Thamrin, C. (2017). Automated Quality Control of Forced Oscillation Measurements: Respiratory Artifact Detection with Advanced Feature Extraction. Journal of Applied Physiology, 123(4), 781-789. [More Information]
  • Kaminsky, D., Wang, L., Bates, J., Thamrin, C., Shade, D., Dixon, A., Wise, R., Peters, S., Irvin, C. (2017). Fluctuation Analysis of Peak Expiratory Flow and its Association with Treatment Failure in Asthma. American Journal of Respiratory and Critical Care Medicine, 195(8), 993-999. [More Information]
  • Tonga, K., Robinson, P., Farah, C., King, G., Thamrin, C. (2017). In vitro and in vivo functional residual capacity comparisons between multiple-breath nitrogen washout devices. ERJ Open Research, 3, 11. [More Information]
  • Tonga, K., Robinson, P., Farah, C., King, G., Thamrin, C. (2017). In vitro and in vivo functional residual capacity comparisons between multiplebreath nitrogen washout devices. ERS Monograph, 3(4), 1-8. [More Information]
  • Huvanandana, J., Nguyen, C., Thamrin, C., Tracy, M., Hinder, M., McEwan, A. (2017). Prediction of intraventricular haemorrhage in preterm infants using time series analysis of blood pressure and respiratory signals. Scientific Reports, 7, 1-9. [More Information]
  • Thamrin, C., Frey, U., Kaminsky, D., Reddel, H., Seely, A., Suki, B., Sterk, P. (2017). Reply to Complexity Analysis of Respiratory Dynamics. American Journal of Respiratory and Critical Care Medicine, 196(2), 248-249. [More Information]
  • Pham, T., Thamrin, C., Robinson, P., McEwan, A., Leong, P. (2017). Respiratory Artefact Removal in Forced Oscillation Measurements: A Machine Learning Approach. IEEE Transactions On Biomedical Engineering, 64(8), 1679-1687. [More Information]
  • Gobbi, A., Dellaca, R., King, G., Thamrin, C. (2017). Toward Predicting Individual Risk in Asthma Using Daily Home Monitoring of Resistance. American Journal of Respiratory and Critical Care Medicine, 195(2), 265-267. [More Information]
  • Jetmalani, K., Chapman, D., Thamrin, C., Farah, C., Berend, N., Salome, C., King, G. (2016). Bronchodilator responsiveness of peripheral airways in smokers with normal spirometry. Respirology, 21(7), 1270-1276. [More Information]
  • King, G., Thamrin, C. (2016). Complex lung function in severe asthma: Seeing is believing. European Respiratory Journal, 48(2), 294-296. [More Information]
  • Neumann, R., Pillow, J., Thamrin, C., Frey, U., Schulzke, S. (2016). Influence of Respiratory Dead Space on Lung Clearance Index in Preterm Infants. Respiratory Physiology and Neurobiology, 223, 43-48. [More Information]
  • Watts, J., Farah, C., Seccombe, L., Handley, B., Schoeffel, R., Bertolin, A., Dame Carroll, J., King, G., Thamrin, C. (2016). Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects. ERJ Open Research, 2(2), 1-7. [More Information]
  • Thamrin, C., Hardaker, K., Robinson, P. (2016). Multiple breath washout: From renaissance to enlightenment? Pediatric Pulmonology, 51(5), 447-449. [More Information]
  • Nguyen, C., Kim, J., Grunstein, R., Thamrin, C., Wang, D. (2016). Respiratory variability during sleep in methadone maintenance treatment patients. The Journal of Clinical Sleep Medicine, 12(4), 607-616. [More Information]
  • Schermer, T., Robberts, B., Crockett, A., Thoonen, B., Lucas, A., Grootens, J., Smeele5, I., Thamrin, C., Reddel, H. (2016). Should the diagnosis of COPD be based on a single spirometry test? NPJ Primary Care Respiratory Medicine, 26, 1-8. [More Information]
  • Thamrin, C., Frey, U., Kaminsky, D., Reddel, H., Seely, A., Suki, B., Sterk, P. (2016). Systems Biology and Clinical Practice in Respiratory Medicine: The Twain Shall Meet. American Journal of Respiratory and Critical Care Medicine, 194(9), 1053-1061. [More Information]
  • Petrus, N., Thamrin, C., Fuchs, O., Frey, U. (2015). Accuracy of tidal breathing measurement of floright compared to an ultrasonic flowmeter in infants. Pediatric Pulmonology, 50(4), 380-388. [More Information]
  • Neumann, R., Pillow, J., Thamrin, C., Larcombe, A., Hall, G., Schulzke, S. (2015). Influence of Gestational Age on Dead Space and Alveolar Ventilation in Preterm Infants Ventilated with Volume Guarantee. Neonatology, 107(1), 43-49. [More Information]
  • Timmins, S., Diba, C., Schoeffel, R., Salome, C., King, G., Thamrin, C. (2014). Changes in oscillatory impedance and nitrogen washout with combination fluticasone/salmeterol therapy in COPD. Respiratory Medicine, 108(2), 344-350. [More Information]
  • Singer, F., Stern, G., Thamrin, C., Abbas, C., Casaulta, C., Frey, U., Latzin, P. (2013). A new double-tracer gas single-breath washout to assess early cystic fibrosis lung disease. European Respiratory Journal, 41(2), 339-345. [More Information]
  • Robinson, P., Latzin, P., Verbanck, S., Hall, G., Horsley, A., Gappa, M., Thamrin, C., Arets, H., Aurora, P., Fuchs, S., King, G., et al (2013). Consensus statement for inert gas washout measurement using multiple- and single- breath tests. European Respiratory Journal, 41(3), 507-522. [More Information]
  • Timmins, S., Coatsworth, N., Palnitkar, G., Thamrin, C., Farrow, C., Schoeffel, R., Berend, N., Diba, C., Salome, C., King, G. (2013). Day-to-day variability of oscillatory impedance and spirometry in asthma and COPD. Respiratory Physiology and Neurobiology, 185(2), 416-424. [More Information]
  • Larcombe, A., Zosky, G., Thamrin, C., Bozanich, E., Hantos, Z., Sly, P. (2013). Factors influencing the assessment of lung function in mice with influenza-induced lung disease. Influenza and Other Respiratory Viruses, 7(6), 889-894. [More Information]
  • Timmins, S., Diba, C., Thamrin, C., Berend, N., Salome, C., King, G. (2013). The feasibility of home monitoring of impedance with the forced oscillation technique in chronic obstructive pulmonary disease subjects. Physiological Measurement, 34(1), 67-81. [More Information]
  • Thamrin, C., Nydegger, R., Stern, G., Chanez, P., Wenzel, S., Watt, R., FitzPatrick, S., Taylor, D., Frey, U. (2011). Associations between fluctuations in lung function and asthma control in two populations with differing asthma severity. Thorax, 66(12), 1036-1042. [More Information]
  • Stern, G., de Jongste, J., van der Velk, R., Baraldi, E., Carraro, S., Thamrin, C., Frey, U. (2011). Fluctuation phenotyping based on daily fraction of exhaled nitric oxide values in asthmatic children. Journal of Allergy and Clinical Immunology, 128(2), 293-300. [More Information]
  • Fuchs, O., Latzin, P., Thamrin, C., Stern, G., Frischknecht, P., Singer, F., Kieninger, E., Proietti, E., Riedel, T., Frey, U. (2011). Normative data for lung function and exhaled nitric oxide in unsedated healthy infants. European Respiratory Journal, 37(5), 1208-1216. [More Information]
  • Thamrin, C., Zindel, J., Nydegger, R., Reddel, H., Chanez, P., Wenzel, S., FitzPatrick, S., Watt, R., Suki, B., Frey, U. (2011). Predicting future risk of asthma exacerbations using individual conditional probabilities. Journal of Allergy and Clinical Immunology, 127(6), 1494-1502. [More Information]
  • Singer, F., Stern, G., Thamrin, C., Oliver, F., Riedel, T., Gustafsson, P., Frey, U., Latzin, P. (2011). Tidal volume single breath washout of two tracer gases - a practical and promising lung function test. PloS One, 6(3), 1-9. [More Information]
  • Thamrin, C., Stern, G., Frey, U. (2010). Fractals for physicians. Paediatric Respiratory Reviews, 11(2), 123-131. [More Information]
  • Thamrin, C., Stern, G. (2010). New methods: what do they tell us? Fluctuation analysis of lung function. European Respiratory Monograph, 47, 310-324. [More Information]
  • Hutten, G., van Eykern, L., Latzin, P., Thamrin, C., van Aalderen, W., Frey, U. (2010). Respiratory muscle activity related to flow and lung volume in preterm infants compared with term infants. Pediatric Research: international journal of human developmental biology, 68(4), 339-343. [More Information]
  • Thamrin, C., Taylor, D., Jones, S., Suki, B., Frey, U. (2010). Variability of lung function predicts loss of asthma control following withdrawal of inhaled corticosteroid treatment. Thorax, 65(5), 403-408. [More Information]
  • Thamrin, C., Stern, G., Strippoli, M., Kuehni, C., Suki, B., Taylor, D., Frey, U. (2009). Fluctuation analysis of lung function as a predictor of long-term response to beta2-agonists. European Respiratory Journal, 33(3), 486-493. [More Information]
  • Latzin, P., Roth, S., Thamrin, C., Hutten, G., Pramana, I., Kuehni, C., Casaulta, C., Nelle, M., Riedel, T., Frey, U. (2009). Lung volume, breathing pattern and ventilation inhomogeneity in preterm and term infants. PloS One, 4(2), e4635-e4635. [More Information]
  • Thamrin, C., Albu, G., Sly, P., Hantos, Z. (2009). Negative impact of the noseclip on high-frequency respiratory impedance measurements. Respiratory Physiology and Neurobiology, 165(1), 115-118. [More Information]
  • Riedel, T., Kyburz, M., Latzin, P., Thamrin, C., Frey, U. (2009). Regional and overall ventilation inhomogeneities in preterm and term-born infants. Intensive Care Medicine, 35(1), 144-151. [More Information]
  • Thamrin, C., Frey, U. (2008). Effect of bacterial filter on measurement of interrupter resistance in preschool and school-aged children. Pediatric Pulmonology, 43(8), 781-787. [More Information]
  • Thamrin, C., Finucane, K., Singh, B., Hantos, Z., Sly, P. (2008). Volume dependence of high-frequency respiratory mechanics in healthy adults. Annals of Biomedical Engineering, 36(1), 162-170. [More Information]
  • Thamrin, C., Gangell, C., Udomittipong, K., Kusel, M., Patterson, H., Fukushima, T., Schultz, A., Hall, G., Stick, S., Sly, P. (2007). Assessment of bronchodilator responsiveness in preschool children using forced oscillations. Thorax, 62(9), 814-819. [More Information]
  • Thamrin, C., Latzin, P., Sauteur, L., Riedel, T., Hall, G., Frey, U. (2007). Deadspace estimation from CO2 versus molar mass measurements in infants. Pediatric Pulmonology, 42(10), 920-927. [More Information]

2017

  • Huvanandana, J., Thamrin, C., Tracy, M., Hinder, M., Nguyen, C., McEwan, A. (2017). Advanced analyses of physiological signals in the neonatal intensive care unit. Physiological Measurement, 38(10), R253-R279. [More Information]
  • Pham, T., Leong, P., Robinson, P., Gutzler, T., Jee, A., King, G., Thamrin, C. (2017). Automated Quality Control of Forced Oscillation Measurements: Respiratory Artifact Detection with Advanced Feature Extraction. Journal of Applied Physiology, 123(4), 781-789. [More Information]
  • Kaminsky, D., Wang, L., Bates, J., Thamrin, C., Shade, D., Dixon, A., Wise, R., Peters, S., Irvin, C. (2017). Fluctuation Analysis of Peak Expiratory Flow and its Association with Treatment Failure in Asthma. American Journal of Respiratory and Critical Care Medicine, 195(8), 993-999. [More Information]
  • Tonga, K., Robinson, P., Farah, C., King, G., Thamrin, C. (2017). In vitro and in vivo functional residual capacity comparisons between multiple-breath nitrogen washout devices. ERJ Open Research, 3, 11. [More Information]
  • Tonga, K., Robinson, P., Farah, C., King, G., Thamrin, C. (2017). In vitro and in vivo functional residual capacity comparisons between multiplebreath nitrogen washout devices. ERS Monograph, 3(4), 1-8. [More Information]
  • Huvanandana, J., Nguyen, C., Thamrin, C., Tracy, M., Hinder, M., McEwan, A. (2017). Prediction of intraventricular haemorrhage in preterm infants using time series analysis of blood pressure and respiratory signals. Scientific Reports, 7, 1-9. [More Information]
  • Thamrin, C., Frey, U., Kaminsky, D., Reddel, H., Seely, A., Suki, B., Sterk, P. (2017). Reply to Complexity Analysis of Respiratory Dynamics. American Journal of Respiratory and Critical Care Medicine, 196(2), 248-249. [More Information]
  • Pham, T., Thamrin, C., Robinson, P., McEwan, A., Leong, P. (2017). Respiratory Artefact Removal in Forced Oscillation Measurements: A Machine Learning Approach. IEEE Transactions On Biomedical Engineering, 64(8), 1679-1687. [More Information]
  • Gobbi, A., Dellaca, R., King, G., Thamrin, C. (2017). Toward Predicting Individual Risk in Asthma Using Daily Home Monitoring of Resistance. American Journal of Respiratory and Critical Care Medicine, 195(2), 265-267. [More Information]

2016

  • Jetmalani, K., Chapman, D., Thamrin, C., Farah, C., Berend, N., Salome, C., King, G. (2016). Bronchodilator responsiveness of peripheral airways in smokers with normal spirometry. Respirology, 21(7), 1270-1276. [More Information]
  • King, G., Thamrin, C. (2016). Complex lung function in severe asthma: Seeing is believing. European Respiratory Journal, 48(2), 294-296. [More Information]
  • Neumann, R., Pillow, J., Thamrin, C., Frey, U., Schulzke, S. (2016). Influence of Respiratory Dead Space on Lung Clearance Index in Preterm Infants. Respiratory Physiology and Neurobiology, 223, 43-48. [More Information]
  • Watts, J., Farah, C., Seccombe, L., Handley, B., Schoeffel, R., Bertolin, A., Dame Carroll, J., King, G., Thamrin, C. (2016). Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects. ERJ Open Research, 2(2), 1-7. [More Information]
  • Thamrin, C., Hardaker, K., Robinson, P. (2016). Multiple breath washout: From renaissance to enlightenment? Pediatric Pulmonology, 51(5), 447-449. [More Information]
  • Nguyen, C., Kim, J., Grunstein, R., Thamrin, C., Wang, D. (2016). Respiratory variability during sleep in methadone maintenance treatment patients. The Journal of Clinical Sleep Medicine, 12(4), 607-616. [More Information]
  • Schermer, T., Robberts, B., Crockett, A., Thoonen, B., Lucas, A., Grootens, J., Smeele5, I., Thamrin, C., Reddel, H. (2016). Should the diagnosis of COPD be based on a single spirometry test? NPJ Primary Care Respiratory Medicine, 26, 1-8. [More Information]
  • Thamrin, C., Frey, U., Kaminsky, D., Reddel, H., Seely, A., Suki, B., Sterk, P. (2016). Systems Biology and Clinical Practice in Respiratory Medicine: The Twain Shall Meet. American Journal of Respiratory and Critical Care Medicine, 194(9), 1053-1061. [More Information]

2015

  • Petrus, N., Thamrin, C., Fuchs, O., Frey, U. (2015). Accuracy of tidal breathing measurement of floright compared to an ultrasonic flowmeter in infants. Pediatric Pulmonology, 50(4), 380-388. [More Information]
  • Neumann, R., Pillow, J., Thamrin, C., Larcombe, A., Hall, G., Schulzke, S. (2015). Influence of Gestational Age on Dead Space and Alveolar Ventilation in Preterm Infants Ventilated with Volume Guarantee. Neonatology, 107(1), 43-49. [More Information]

2014

  • Timmins, S., Diba, C., Schoeffel, R., Salome, C., King, G., Thamrin, C. (2014). Changes in oscillatory impedance and nitrogen washout with combination fluticasone/salmeterol therapy in COPD. Respiratory Medicine, 108(2), 344-350. [More Information]

2013

  • Singer, F., Stern, G., Thamrin, C., Abbas, C., Casaulta, C., Frey, U., Latzin, P. (2013). A new double-tracer gas single-breath washout to assess early cystic fibrosis lung disease. European Respiratory Journal, 41(2), 339-345. [More Information]
  • Robinson, P., Latzin, P., Verbanck, S., Hall, G., Horsley, A., Gappa, M., Thamrin, C., Arets, H., Aurora, P., Fuchs, S., King, G., et al (2013). Consensus statement for inert gas washout measurement using multiple- and single- breath tests. European Respiratory Journal, 41(3), 507-522. [More Information]
  • Timmins, S., Coatsworth, N., Palnitkar, G., Thamrin, C., Farrow, C., Schoeffel, R., Berend, N., Diba, C., Salome, C., King, G. (2013). Day-to-day variability of oscillatory impedance and spirometry in asthma and COPD. Respiratory Physiology and Neurobiology, 185(2), 416-424. [More Information]
  • Larcombe, A., Zosky, G., Thamrin, C., Bozanich, E., Hantos, Z., Sly, P. (2013). Factors influencing the assessment of lung function in mice with influenza-induced lung disease. Influenza and Other Respiratory Viruses, 7(6), 889-894. [More Information]
  • Timmins, S., Diba, C., Thamrin, C., Berend, N., Salome, C., King, G. (2013). The feasibility of home monitoring of impedance with the forced oscillation technique in chronic obstructive pulmonary disease subjects. Physiological Measurement, 34(1), 67-81. [More Information]

2011

  • Thamrin, C., Nydegger, R., Stern, G., Chanez, P., Wenzel, S., Watt, R., FitzPatrick, S., Taylor, D., Frey, U. (2011). Associations between fluctuations in lung function and asthma control in two populations with differing asthma severity. Thorax, 66(12), 1036-1042. [More Information]
  • Stern, G., de Jongste, J., van der Velk, R., Baraldi, E., Carraro, S., Thamrin, C., Frey, U. (2011). Fluctuation phenotyping based on daily fraction of exhaled nitric oxide values in asthmatic children. Journal of Allergy and Clinical Immunology, 128(2), 293-300. [More Information]
  • Fuchs, O., Latzin, P., Thamrin, C., Stern, G., Frischknecht, P., Singer, F., Kieninger, E., Proietti, E., Riedel, T., Frey, U. (2011). Normative data for lung function and exhaled nitric oxide in unsedated healthy infants. European Respiratory Journal, 37(5), 1208-1216. [More Information]
  • Thamrin, C., Zindel, J., Nydegger, R., Reddel, H., Chanez, P., Wenzel, S., FitzPatrick, S., Watt, R., Suki, B., Frey, U. (2011). Predicting future risk of asthma exacerbations using individual conditional probabilities. Journal of Allergy and Clinical Immunology, 127(6), 1494-1502. [More Information]
  • Singer, F., Stern, G., Thamrin, C., Oliver, F., Riedel, T., Gustafsson, P., Frey, U., Latzin, P. (2011). Tidal volume single breath washout of two tracer gases - a practical and promising lung function test. PloS One, 6(3), 1-9. [More Information]

2010

  • Thamrin, C., Stern, G., Frey, U. (2010). Fractals for physicians. Paediatric Respiratory Reviews, 11(2), 123-131. [More Information]
  • Thamrin, C., Stern, G. (2010). New methods: what do they tell us? Fluctuation analysis of lung function. European Respiratory Monograph, 47, 310-324. [More Information]
  • Hutten, G., van Eykern, L., Latzin, P., Thamrin, C., van Aalderen, W., Frey, U. (2010). Respiratory muscle activity related to flow and lung volume in preterm infants compared with term infants. Pediatric Research: international journal of human developmental biology, 68(4), 339-343. [More Information]
  • Thamrin, C., Taylor, D., Jones, S., Suki, B., Frey, U. (2010). Variability of lung function predicts loss of asthma control following withdrawal of inhaled corticosteroid treatment. Thorax, 65(5), 403-408. [More Information]

2009

  • Thamrin, C., Stern, G., Strippoli, M., Kuehni, C., Suki, B., Taylor, D., Frey, U. (2009). Fluctuation analysis of lung function as a predictor of long-term response to beta2-agonists. European Respiratory Journal, 33(3), 486-493. [More Information]
  • Latzin, P., Roth, S., Thamrin, C., Hutten, G., Pramana, I., Kuehni, C., Casaulta, C., Nelle, M., Riedel, T., Frey, U. (2009). Lung volume, breathing pattern and ventilation inhomogeneity in preterm and term infants. PloS One, 4(2), e4635-e4635. [More Information]
  • Thamrin, C., Albu, G., Sly, P., Hantos, Z. (2009). Negative impact of the noseclip on high-frequency respiratory impedance measurements. Respiratory Physiology and Neurobiology, 165(1), 115-118. [More Information]
  • Riedel, T., Kyburz, M., Latzin, P., Thamrin, C., Frey, U. (2009). Regional and overall ventilation inhomogeneities in preterm and term-born infants. Intensive Care Medicine, 35(1), 144-151. [More Information]

2008

  • Thamrin, C., Frey, U. (2008). Effect of bacterial filter on measurement of interrupter resistance in preschool and school-aged children. Pediatric Pulmonology, 43(8), 781-787. [More Information]
  • Thamrin, C., Finucane, K., Singh, B., Hantos, Z., Sly, P. (2008). Volume dependence of high-frequency respiratory mechanics in healthy adults. Annals of Biomedical Engineering, 36(1), 162-170. [More Information]

2007

  • Thamrin, C., Gangell, C., Udomittipong, K., Kusel, M., Patterson, H., Fukushima, T., Schultz, A., Hall, G., Stick, S., Sly, P. (2007). Assessment of bronchodilator responsiveness in preschool children using forced oscillations. Thorax, 62(9), 814-819. [More Information]
  • Thamrin, C., Latzin, P., Sauteur, L., Riedel, T., Hall, G., Frey, U. (2007). Deadspace estimation from CO2 versus molar mass measurements in infants. Pediatric Pulmonology, 42(10), 920-927. [More Information]

To update your profile click here. For support on your academic profile contact .